Description:
UV ozone sensor module has the characteristics of long life, high accuracy and no oxygen dependence, which has been used as the standard method for ozone analysis in the United States and other countries. UV ozone sensor has low price and can be continuously monitored for a long time. It has a wide range of applications, and can be used in hospitals, pharmaceutical factories, factories and other occasions.
Sensor principle:
After the ultraviolet radiation from the ultraviolet light source is absorbed by a certain concentration of the gas to be measured, the spectral intensity in direct proportion to the gas concentration will change. Therefore, the concentration of the gas to be measured can be inversed by calculating the variation of the spectral intensity. UV ozone sensor module is a universal UV-0 sensor module, which is based on the detection principle of UV absorption technology and combines advanced optical path, precision circuit and intelligent software
Features:
(1)Performance stability continuous monitoring
JX-O3-103 series is a kind of sensor which uses ultraviolet absorption technology to measure ozone (O3) content in air.
(2)UV light source / UV detector
UV O3 sensor module uses UV light source and UV detector to process the measurement and reference signals.
(3)No oxygen dependence
UV O3 sensor module uses high quality chip, accurate measurement, no oxygen dependence, low power consumption.Fearless of harsh environment.Even in harsh temperature and environmental conditions, stable and reliable measurement results can be obtained.
(4)Supporting secondary development
The product supports secondary development and can be customized without secondary calibration.
(5)Stainless steel polishing process
The product is made of stainless steel polishing process, stable performance, can be used in a variety of environments, waterproof and corrosion resistant.
Application:
UV O3 can be widely used in ozone disinfection equipment, air detection and chemical gas production process monitoring, and can be installed in breeding plants, ventilation system, refrigerated storage and other applications.
Product images and details:
Technical Parameters:
Parameter name | Parameter content |
---|---|
Measuring range | 0-200PPM (default) /0-1000PPM |
Measurement resolution | 1ppm |
Response time | <30S(25°C) |
Measurement accuracy | 0.1PPM (default) /0.5PPM |
Preheat time | <5min(25°C) |
Reach accuracy | <10min(25°C) |
Operating Voltage | 9-24V DC |
Average power consumption | <50mA |
Working humidity | 0~95%RH (non-condensing) |
Operating temperature | -10~60°C |
storage temperature | -20~70°C |